Product Description

CleanBurn Vented Natural Gas Logs are the perfect addition to any fully vented, solid-fuel burning fireplace to add a contemporary and stylish look to new or existing construction! Kick the hassle and mess of burning wood, and replace it with a clean, efficient natural gas burning log set. CleanBurn's Mountain Oak ceramic logs are hand-crafted, steel bar reinforced, and resist heat up to 2300° F. These hand-colored logs are designed with heavy bark, split oak, and charred wood features which are colored with a multi-step process incorporating more than six color combinations. They utilize environmentally friendly, non-paint-based ceramic colorations, which last while under long firing cycles, and do not create any odor when burned.

The best part? There are NO ADDITIONAL PURCHASES required; everything that you need for installation and operation are included with your CleanBurn Vented Natural Gas Log purchase! Choose from 18" (43,000 BTUs/Hour) or 24" log sizes (72,000 BTUs/Hour) by referring to the minimum fireplace requirements below. This product is perfect for professionals and DIY'ers alike! This product meets all codes and standards for the American National Standards Institute code Z21.84-2017 for Manually Lighted, Natural Gas, Decorative Gas Appliances for Installation in Solid-Fuel Burning Fireplaces.

CLEANBURN VENTED GAS LOGS FEATURE:
 

  • No Additional Purchases Required! Everything You Need in ONE Box!
  • Hand-Painted, Steel Bar Reinforced, Ceramic Logs
  • Two Available Sizes Capable of 43,000 - 72,000 BTUs / Hour
  • Easily Convert Your Wood Burning Fireplace
  • Natural Gas, Match Lit Only!
  • Includes SPK1-N Manual Safety Pilot Kit
  • Meets All Standards for ANSI Z21.84

EVERYTHING INCLUDED WITH YOUR PURCHASE:
 
  • Designer Series, Mountain Oak Ceramic Logs: Front Log, Rear Log, Top Logs (18" Set - 3 Top Logs; 24" Set - 4 Top Logs)
  • Burner Pan & Fireplace Grate
  • Bag of Sand & Bag of Glowing Embers
  • SPK1-N Manual Safety Pilot Kit
  • Installation & Operation Manual
  • Installation Kit: Flexible Gas Line Connector, Fitting for 1/2" Gas Line, Orifice Holder, Orifice Spud, Damper Clamp, Plug, Rating/Identification Plate

MINIMUM FIREPLACE REQUIREMENTS BY LOG SIZE:

CleanBurn Vented Natural Gas Log Set - 18"
 
  • Opening Height: 16"
  • Firebox Depth: 13"
  • Front Firebox Width: 24"
  • Rear Firebox Width: 18"
  • Chimney Diameter: 7"
  • Min. Permanent Chimney Opening: 39 Sq. Inches
  • BTU/Hour, Natural Gas: 43,000

CleanBurn Vented Natural Gas Log Set - 24"
 
  • Opening Height: 16"
  • Firebox Depth: 13"
  • Front Firebox Width: 30"
  • Rear Firebox Width: 24"
  • Chimney Diameter: 7"
  • Min. Permanent Chimney Opening: 51 Sq. Inches
  • BTU/Hour, Natural Gas: 72,000

IMPORTANT GUIDELINES:
  • The chimney damper must be wide open and fixed in a manner to maintain a permanent free opening at all times
  • The area of the flue must be not less than 1/10 the area of the fireplace opening
  • This gas log set must be installed in fully VENTED metal or masonry fireplace with a working flue that is safe for burning a wood fire
  • The flue must be free of any obstructions and must exhaust all products of combustion
  • At least 12” of noncombustible or heat resistant material is required above the fireplace. A fireplace hood will be required to act as a heat deflector in protecting combustible fireplace surrounds (facing and/or mantel) if certain minimum clearances cannot be met 
  • Be certain that combustible flooring material (i.e., carpet, tile etc.) is not too close to this gas appliance. If this appliance is at floor level or less than 6” above the floor, there must be at least 12” of noncombustible material between the base of the fireplace and any combustible flooring
  • Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft. refer to the National Fuel Gas Code, or visit www.nfpa.org
  • The gas appliance and it’s main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system as required by NFPA 54

Review Owner's Manual for additional information regarding installation and maintenance

Technical Specifications

EVERYTHING INCLUDED WITH YOUR CLEANBURN VENTED NATURAL GAS LOGS:

  • Designer Series, Mountain Oak Ceramic Logs: Front Log, Rear Log, Top Logs (18" Set - 3 Top Logs; 24" Set - 4 Top Logs)
  • Burner Pan & Fireplace Grate
  • Bag of Sand & Bag of Glowing Embers
  • SPK1-N Manual Safety Pilot Kit
  • Installation & Operation Manual
  • Installation Kit: Flexible Gas Line Connector, Fitting for 1/2" Gas Line, Orifice Holder, Orifice Spud, Damper Clamp, Plug, Rating/Identification Plate


MINIMUM FIREPLACE REQUIREMENTS BY LOG SIZE:


CleanBurn Vented Natural Gas Log Set - 18"

  • Opening Height: 16"
  • Firebox Depth: 13"
  • Front Firebox Width: 24"
  • Rear Firebox Width: 18"
  • Chimney Diameter: 7"
  • Min. Permanent Chimney Opening: 39 Sq. Inches
  • BTU/Hour, Natural Gas: 43,000


CleanBurn Vented Natural Gas Log Set - 24"

  • Opening Height: 16"
  • Firebox Depth: 13"
  • Front Firebox Width: 30"
  • Rear Firebox Width: 24"
  • Chimney Diameter: 7"
  • Min. Permanent Chimney Opening: 51 Sq. Inches
  • BTU/Hour, Natural Gas: 72,000


IMPORTANT GUIDELINES:

  • The chimney damper must be wide open and fixed in a manner to maintain a permanent free opening at all times
  • The area of the flue must be not less than 1/10 the area of the fireplace opening
  • This gas log set must be installed in fully VENTED metal or masonry fireplace with a working flue that is safe for burning a wood fire
  • The flue must be free of any obstructions and must exhaust all products of combustion
  • At least 12” of noncombustible or heat resistant material is required above the fireplace. A fireplace hood will be required to act as a heat deflector in protecting combustible fireplace surrounds (facing and/or mantel) if certain minimum clearances cannot be met 
  • Be certain that combustible flooring material (i.e. carpet, tile etc.) is not too close to this gas appliance. If this appliance is at floor level or less than 6” above the floor, there must be at least 12” of noncombustible material between the base of the fireplace and any combustible flooring
  • Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft. refer to the National Fuel Gas Code, or visit www.nfpa.org
  • The gas appliance and it’s main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system as required by NFPA 54
  • Review Owner's Manual for additional information regarding installation and maintenance

Product Specifics

Test

Ratings & Reviews

No reviews available

Be the first to Write a Review